Eclopidia

ELEMENTS LABORATORY

Explore matter, one question at a time.

Choose an element, compare two records, try a counting exercise or explore a recorded particle event.

The room and atomic displays are educational models. Element records and recorded particle events have separate sources and limits, described below.

Start here

Open Elements from the Earth Systems menu. The laboratory brings together the same 118 element records used elsewhere in Eclopidia. The room is artwork; the element facts and recorded collision data have separate sources.

On a first visit, the periodic wall board opens in an expanded view and the shared periodic table is open in the details area. Choose an element to move into Inspect, or choose another station. The shared table provides the larger keyboard and touch targets.

Go to lab station is a persistent selector for the wall board, every experiment and Periodic trends. Front view holds the station steady while you operate it; scroll or pinch to zoom. Choose Free orbit to drag around it. Outside Build a molecule, arrow-key rotation also leaves Front view. The recorded Collision and Build a molecule stations start in Front view. In Build a molecule, drag or use left/right arrows to turn the model while the room stays steady; scroll or pinch to zoom. Fit (or F) immediately restores the model to the front. Choosing the same station again preserves its current zoom.

Use the view buttons:

Selecting a station expands it to the available screen. Restore page view or Escape returns to the page while keeping the current station. Return to room selects Lab overview. The station’s Back to Lab overview button does the same. Expand station opens the larger view again. Fit frames the current experiment, rather than taking you back to the room. On a phone, the experiment fits above its records; scroll the details area to read more.

Only the chosen view is mounted. A selected lab element is retained when switching between the lab and Earth context. Following an element's encyclopedia link opens its own record address; the page heading and source record belong to that address. Exploring another element inside the lab does not silently change that saved address.

The Periodic Table menu link opens the shared table directly. Selecting a cell opens that element’s record and Inspect station. Browser Back returns to the table.

Choose an element

Tap Choose an element from the periodic table to open the shared table. Select a named cell. On a narrow screen, scroll the table sideways; it preserves the real periodic arrangement instead of squeezing all 18 columns into unreadable targets. The accessible selector has 48 px cells. On a phone, the station buttons form a horizontal strip; swipe that strip to reach buttons farther along it.

You can also choose Focus periodic board to bring the room's wall board closer, tap a cell, then return from the board. A drag or pinch moves the camera; it should not select a cell. The projected 3D board cells are not a replacement for the larger shared-table controls.

Selecting an element from Lab overview enters Inspect. No game progress or discovery unlock is changed.

Inspect an atom

Choose Inspect an atom. Read the selected element's properties, units, sources and review date next to its schematic model. Drag to orbit, use the zoom buttons, and choose Fit if the view becomes awkward. On a keyboard, focus the 3D view: arrow keys rotate, + or = zooms in, − or _ zooms out, and F or Home fits the view. Use Tab to reach the ordinary controls. These shortcuts do not replace browser commands using Ctrl, Alt or the command key.

The chambers do not show a photograph of an atom. Their geometry, shell sizes, light, motion and spacing are illustrations. Neutral shell counts are derived only when the source electron configuration can be parsed. A missing source value stays unavailable. Neutrons are not guessed: their count depends on the isotope, and this registry does not supply the isotope needed for that calculation.

Compare elements

Choose Compare elements. The active slot determines whether a board or shared-table choice fills A or B. Use Slot A or Slot B to change the target. Choose two elements and read their properties side by side. The selected slot must remain clear after either input method.

Choose the visible Chamber A or Chamber B label, or tap the chamber body, to select that slot and open the shared table. Empty chambers say so. A drag, long press or multi-finger gesture should not select a chamber.

A visual difference between the two chambers is not a measured atomic-size comparison. Read the property labels and units; unavailable values do not become zero.

Build a molecule model

Choose Build a molecule from Go to lab station. Start with three element inputs; Add input supports up to eight, and additional inputs can be removed. Each input takes a whole-number atom count from 0 to 120. Choose its element using the row selector or focus that row and use the shared periodic table. The table states which input it will fill.

Choose one of the supported models, Water (H₂O) or Methanol (CH₄O), and 1–12 model molecules. Fill example quantities fills the corresponding counts but does not build anything. Then choose Build model. One water model needs 2 hydrogen atoms and 1 oxygen atom. One methanol model uses 4 hydrogen atoms, 1 carbon atom and 1 oxygen atom; it is shown only as a structure example.

The separate Result chamber shows the chosen structure and an accounting table: provided, used and unused atoms. Repeated inputs of the same element are added together. Insufficient atoms are listed as missing, nothing is consumed and no model is drawn. Editing inputs clears the previous result; build again to check the new counts. Two water models, for example, need 4 hydrogen and 2 oxygen atoms. Any extra carbon remains unused.

These are selected supported structures, not a general reaction engine. Composition alone does not uniquely identify every compound. The station checks atom counts against the model you chose; it does not predict what physically forms or give synthesis instructions. Counts represent individual atoms and molecules in this model, not moles, bulk quantities or reaction coefficients.

Computed 3-D models come from PubChem conformer records, not measured or experimental geometry. Source geometry is retained; centring, uniform scaling and turning are viewing transforms; sphere sizes, colours and spacing between repeated molecules are display choices. Atom labels identify the first copy; the text result lists every atom and bond. Atom labels show near the front in Front view and hide when the model turns away or you choose Free orbit. Fit restores the model and labels to the front. A narrow or unavailable 3D view does not remove the complete text accounting. Use Expand station for a larger view.

Source: National Library of Medicine; National Institutes of Health; U.S. Department of Health and Human Services. Snapshot 13 November 2026. Water: PubChem CID962; methanol: PubChem CID887. References: Kim et al., PubChem2025 update; Bolton et al., PubChem3D. No NLM, NIH or PubChem endorsement is implied. Exact retained source-file hashes appear in the station.

Charge count

Choose Charge count. The proton count Z comes from the selected element's atomic number. Change the electron count Ne with the stepper or its number field. The displayed arithmetic is:

q = Z − Ne, in units of the elementary charge e.

For example, 6 protons and 7 electrons give a net count of −1 e. The exercise bounds Ne between 0 and Z+8 for interaction; this is not a chemical limit. It does not predict ion stability, reactions or ion electron configuration. Tokens represent counts, not particle positions or orbitals.

When you type a count, Tab or Shift+Tab commits it before moving to the next control. A count outside the exercise range moves to its nearest limit; an empty or non-integer entry returns to neutral. At a limit, the unavailable − or + control is skipped by Tab.

Choose Back to the neutral count to set Ne=Z. Selecting a different element also returns the exercise to that element's neutral count.

Recorded collision station

Choose Collision station, then select one of the four recorded CMS candidate events. The event selector lists channel, run and event identifiers. The panel gives the stored GMT timestamp and source file.

Select a candidate row to inspect its recorded values and highlight its direction. A checkbox controls whether that candidate contributes to the displayed invariant mass. Clear selection removes the current subset; Restore all restores all candidates for the current event. Selecting another event replaces the previous event's candidates; candidates are not combined across events.

The calculation uses M²=(ΣE)²−|Σp|² with c=1. Energies and momenta are expressed in GeV under this convention; mass is given in GeV, or GeV/c² when c is written explicitly. The displayed number is a calculation for the selected recorded four-vectors, not a simulated new collision or proof of a discovered particle.

The lines show normalized momentum directions. They share an origin and equal length; their appearance is not detector scale, energy-scaled length, curved-track reconstruction or measured flight time. The reveal animation only reveals lines. The detector shell is decorative, can be hidden, and is not a model of the real LHC or CMS apparatus.

Data credit: CMS Collaboration / CERN Open Data; Thomas McCauley (2014), “Higgs candidate events for use in education and outreach”, record 300, DOI 10.7483/OPENDATA.CMS.N9MJ.QEEC, CC0-1.0. No CERN/CMS endorsement is implied. Only the curated channel candidates are included; other detector objects and historic position geometry are omitted.

If 3D does not work

If the adapter cannot load, choose Read element records without 3D. The existing registry remains usable from the same loaded 118 records. Retry laboratory retries the adapter; Retry element records retries the authoritative data when the data itself is unavailable. A source-data outage cannot be repaired by inventing replacement values.

If the browser has no WebGL, use the lab's text fallback or the separate Element records view. Text and controls remain the primary way to inspect facts. Use Element records if 3D controls are unavailable or uncomfortable.

Scope and credits

Element identities/properties: existing Eclopidia PubChem/NCBI records with IUPAC naming attribution; use each record's own source/review information. The lab does not add a new chemistry registry. Presence of an element does not establish abundance, a health effect, safety, biological function or a legal threshold.

The room’s wood, brass, glass, furniture and lighting are artwork, not samples of the selected element. The room, lighting and apparatus are artistic. The renderer is Three.js (MIT), with the licence retained in the release. New gravity, quantum, electrical, optical and reaction experiments remain future directions; these stations do not claim those capabilities.

Official references

Laboratory software

The 3D laboratory uses Three.js, Copyright 2010–2024 Three.js Authors, under the MIT licence. Read the full Three.js licence.